(1) [Condition] page
Figure 3.27 [Trace Acquisition Properties] Dialog Box ([Condition] Page)
[Sequential Trace Stop]: Use this option to set a sequential trace stop by using channels 1 to 7. The sequential
trace stop function allows trace acquisition to stop when the conditions of several
channels are satisfied in the specified order. Two to seven pass points and one reset
point are selectable as sequential trace stop conditions. The conditions are satisfied in
the order of 1 to 7. To use a sequential trace stop, select the checkbox of the channel.
To set a reset condition, select the [Reset Point] checkbox. Channel 8 is used for a
reset condition. When a reset condition is satisfied, all the sequential trace stop
conditions that have been satisfied will be cleared and the emulator starts checking
the first condition again. When a sequential trace stop is enabled, no setting is
available for the channels (out of 1 to 7) that are not used for the sequential trace stop
function.
[Run time count between trigger outputs]:
Selects channels for use in execution time measurement. Clicking [Use] allows
measurement of time in tracing. There are four types of channel combinations
consisted of those for the start and the end of measurement: 1-2, 3-4, 5-6, and 7-8.
[Free trace]: Selects the free trace mode. When [Free trace] is enabled, any trace acquisition
condition set will be ignored.
[Back]: Puts the setting back to the previous state at the time the dialog box has been
displayed.