54
[Clock/8]: Time stamping is in terms of the number of bus-clock cycles, i.e., is
synchronized with 1/8 cycle of the system clock signal (φ).
[Selection of the trace contents]:
Selects whether or not to display time stamps, IRQs, or executed instructions.
[Time stamp]: Displays IRQs if the level of any of IRQ7-0 is low. This allows any 32-bit
time stamp information to be displayed.
[IRQ7-0 all indications]: Displays the status of IRQ7-0 in bit units. Lower 16 bits of time stamps are
fixed to 0.
[Suppress]: Acquires no DMAC/DTC cycles or AUD cycles.