Renesas FP-100B Informações Técnicas

Consulte online ou descarregue Informações Técnicas para não Renesas FP-100B. Renesas FP-100B Technical information Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 30
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Vista de página 0
1 2 3 4 5 6 ... 29 30

Resumo do Conteúdo

Página 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Página 2

V WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emul

Página 3 - To all our customers

Cautions 1. Hitachi neither warrants nor grants licenses of any rights of Hitachi’s or any third party’s patent, copyright, trademark, or other inte

Página 5

i Preface Thank you for purchasing this user system interface cable (HS3887ECH61H) for the Hitachi’s original microcomputer H8/3887 series. The HS388

Página 6 - IMPORTANT INFORMATION

ii Contents Section 1 Configuration...1 Section 2 Connection P

Página 7 - DISCLAIMER

1 Section 1 Configuration CAUTION Use an IC149-100-054-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100B or T

Página 8

2 Table 1 lists the HS3887ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS3887ECH61H Components No.

Página 9 - SAFETY PAGE

3 Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below.

Página 10

4 Figure 2 Connecting User System Interface Cable to Emulator Station

Página 11 - Cautions

5 2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USE

Página 12

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Página 13 - Preface

6 2.2.4 Fastening Cable Head CAUTION 1. Use a Philips-type screwdriver whose head matches the screw head. 2. The tightening torque must b

Página 14 - Contents

7 Cable headUser system Figure 3 Connecting User System Interface Cable to User System

Página 15 - CAUTION

8 2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable bodyCable headRemove jigPush the remove jig.RemovingUser system Figure

Página 16

9 2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system w

Página 17

10 2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Figure 6

Página 18

11 2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable

Página 19

12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver

Página 20

13 MCUPin 1IC socket (IC149-100-054-B51manufactured by YAMAICHI ELECTRONICS Co., Ltd.)User systemScrews (M2.6 x 6 mm)with flat washersSocket cover Fi

Página 21 - User system

14 Section 4 Verifying Operation 1. When using the H8/3864 series and H8/3887 series E6000 emulator (HS3880EPI60H and HS388REPI60H), turn on the e

Página 22 - 2.2.5 Fastening Cable Body

15 Figure 9 shows the system clock oscillator on the user system interface cable and the subclock input specifications. R2 270R1 1 MHCU04HCU04To E600

Página 23 - 24 = 12.00

Regarding the change of names mentioned in the document, such as Hitachi Electric and Hitachi XX, to Renesas Technology Corp.The semiconductor operati

Página 24

16 Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the ca

Página 25

H8/3887 Series FP-100B/TFP-100BUser System Interface Cable(HS3887ECH61H) for E6000 EmulatorUser’s ManualUser’s ManualRev.0.1 2000.09

Página 27

I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy

Página 28

II LIMITED WARRANTY Hitachi warrants its user system interface cables to be manufactured in accordance with published specifications and f

Página 29

III State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages,

Página 30 - Section 5 Notice

IV SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for futur

Comentários a estes Manuais

Sem comentários