To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Vista de página 0
1 2 3 4 5 6 ... 27 28

Resumo do Conteúdo

Página 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Página 2

Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other inte

Página 4

i Preface Thank you for purchasing this user system interface cable (HS2615ECH61H) for the Renesas’s original microcomputer H8S/2615 series. The HS26

Página 5 - IMPORTANT INFORMATION

ii Contents Section 1 Configuration...1 Section 2 Connection P

Página 6 - DISCLAIMER

1 Section 1 Configuration CAUTION Use an IC149-080-017-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-80Q package

Página 7

2 Table 1 lists the HS2615ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS2615ECH61H Components No.

Página 8 - SAFETY PAGE

3 Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below.

Página 9

4 Emulator stationE6000Cable body connectorUser system interface cable Figure 2 Connecting User System Interface Cable to Emulator Station

Página 10 - Cautions

5 2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USE

Página 11

6 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-80Q package on the us

Página 12 - Preface

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Página 13 - Contents

7 Fasten the user system interface cable head to the IC socket for an FP-80Q package on the user system with the four screws (M2 x 12 mm; with four f

Página 14 - CAUTION

8 2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable bodyCable headRemove jigPush the remove jigUser systemRemoving Figure 4

Página 15

9 2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system w

Página 16

10 2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Uni

Página 17 - User system interface cable

11 2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable

Página 18

12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver

Página 19

13 MCUPin 1IC socket (IC149-080-017-B5manufactured by YAMAICHI ELECTRONICS Co., Ltd.)User systemScrews (M2 x 8 mm) with flat washersSocket cover Figu

Página 20

14 Section 4 Verifying Operation 1. Turn on the emulator according to the procedures described in the H8S Series E6000 Emulator User's Manual

Página 21 - 2.2.5 Fastening Cable Body

15 Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the ca

Página 22 - 0.65 ± 0.05

H8S/2615 Series FP-80Q User System Interface Cable (HS2615ECH61H) for E6000 EmulatorUser’s ManualUser’s ManualRev.2.0 2003.04

Página 24 - 9.4 21.5

I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy

Página 25

II LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and free

Página 26

III State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so

Página 27

IV SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for futur

Página 28 - Section 5 Notice

V WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emul