To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas
Electronics Corporation took over all the business of both
companies.
Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Vista de página 0
1 2 3 4 5 6 ... 35 36

Resumo do Conteúdo

Página 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Página 2

Rev. 3.00 Sep. 08, 2008 Page IV of VI REJ10J1396-0300 SAFETY PAGE READ FIRST • READ this user's manual before using this user system interfac

Página 3 - User’s Manual

Rev. 3.00 Sep. 08, 2008 Page V of VI REJ10J1396-0300 WARNING Observe the precautions listed below. Failure to do so will result in a FIR

Página 4

Rev. 3.00 Sep. 08, 2008 Page VI of VI REJ10J1396-0300

Página 5

Preface The HS1582ECH61H is a user system interface cable that connects an H8SX/1582 E6000H emulator (HS1527KEPH60H; hereinafter referred to as the em

Página 6

Contents Section 1 Configuration...1 Section 2 Connection Proc

Página 7 - IMPORTANT INFORMATION

Section 1 Configuration Rev. 3.00 Sep. 08, 2008 Page 1 of 18 REJ10J1396-0300 Section 1 Configuration CAUTION Use an NQPACK120SE-ND socket

Página 8 - DISCLAIMER

Section 1 Configuration Rev. 3.00 Sep. 08, 2008 Page 2 of 18 REJ10J1396-0300 Table 1 lists the HS1582ECH61H components. Please make sure you ha

Página 9

Section 2 Connection Procedures Rev. 3.00 Sep. 08, 2008 Page 3 of 18 REJ10J1396-0300 Section 2 Connection Procedures 2.1 Connecting User Sys

Página 10 - SAFETY PAGE

Section 2 Connection Procedures Rev. 3.00 Sep. 08, 2008 Page 4 of 18 REJ10J1396-0300 2. After making sure the direction of the cable body conne

Página 11 - REJ10J1396-0300

Section 2 Connection Procedures Rev. 3.00 Sep. 08, 2008 Page 5 of 18 REJ10J1396-0300 2.2 Connecting User System Interface Cable to User System

Página 12 - REJ10J1396-0300

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Página 13 - Preface

Section 2 Connection Procedures Rev. 3.00 Sep. 08, 2008 Page 6 of 18 REJ10J1396-0300 Use the guide pins provided to determine where to install t

Página 14 - Contents

Section 2 Connection Procedures Rev. 3.00 Sep. 08, 2008 Page 7 of 18 REJ10J1396-0300 2.2.3 Inserting Cable Head CAUTION Check the location

Página 15 - CAUTION

Section 2 Connection Procedures Rev. 3.00 Sep. 08, 2008 Page 8 of 18 REJ10J1396-0300 Fasten the user system interface cable head to the IC socke

Página 16 - Section 1 Configuration

Section 2 Connection Procedures Rev. 3.00 Sep. 08, 2008 Page 9 of 18 REJ10J1396-0300 2.2.5 Fastening Cable Body Connect the cable body to the

Página 17

Section 2 Connection Procedures Rev. 3.00 Sep. 08, 2008 Page 10 of 18 REJ10J1396-0300 2.3 Recommended Dimensions for User System Mount Pad Figu

Página 18 - HS1527KEPH60H

Section 2 Connection Procedures Rev. 3.00 Sep. 08, 2008 Page 11 of 18 REJ10J1396-0300 2.4 Dimensions for User System Interface Cable Head The

Página 19

Section 2 Connection Procedures Rev. 3.00 Sep. 08, 2008 Page 12 of 18 REJ10J1396-0300 2.5 Resulting Dimensions after Connecting User System Int

Página 20

Section 3 Installing the MCU to the User System Rev. 3.00 Sep. 08, 2008 Page 13 of 18 REJ10J1396-0300 Section 3 Installing the MCU to the Use

Página 21

Section 3 Installing the MCU to the User System Rev. 3.00 Sep. 08, 2008 Page 14 of 18 REJ10J1396-0300 MCUPin 1IC socket (NQPACK120SE-NDmanufactu

Página 22

Section 4 Verifying Operation Rev. 3.00 Sep. 08, 2008 Page 15 of 18 REJ10J1396-0300 Section 4 Verifying Operation 1. Turn on the emulator ac

Página 23 - 2.2.5 Fastening Cable Body

H8SX/1582 PLQP0120LA-AUser System Interface CableHS1582ECH61H User’s ManualUser’s Manual Rev.3.00 2008.09Renesas Microcomputer Development Environme

Página 24 - 17.0 min

Section 4 Verifying Operation Rev. 3.00 Sep. 08, 2008 Page 16 of 18 REJ10J1396-0300

Página 25 - 23.020.25

Section 5 Notice Rev. 3.00 Sep. 08, 2008 Page 17 of 18 REJ10J1396-0300 Section 5 Notice 1. Make sure that pin 1 on the user system IC socket

Página 26 - 13.3 21.5

Section 5 Notice Rev. 3.00 Sep. 08, 2008 Page 18 of 18 REJ10J1396-0300 P4 short connector. For details on the differences between the target MC

Página 27

H8SX/1582 PLQP0120LA-AUser System Interface CableHS1582ECH61H User's ManualPublication Date: Rev.1.00, June 15, 2004

Página 28

Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japanhttp://www.renesas.comRefer to

Página 30

1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 JapanH8SX/1582 PLQP0120LA-AUser System Interface CableREJ10J1396-0300HS1582ECH61H Use

Página 31 - Section 5 Notice

Rev. 3.00 Sep. 08, 2008 Page ii of vi REJ10J1396-0300

Página 32

Rev. 3.00 Sep. 08, 2008 Page iii of vi REJ10J1396-0300 1. This document is provided for reference purposes only so that Renesas customers may s

Página 33 - User System Interface Cable

Rev. 3.00 Sep. 08, 2008 Page iv of vi REJ10J1396-0300

Página 34 - RENESAS SALES OFFICES

Rev. 3.00 Sep. 08, 2008 Page I of VI REJ10J1396-0300 IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user syste

Página 35

Rev. 3.00 Sep. 08, 2008 Page II of VI REJ10J1396-0300 LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured

Página 36 - HS1582ECH61H User’s Manual

Rev. 3.00 Sep. 08, 2008 Page III of VI REJ10J1396-0300 State Law: Some states do not allow the exclusion or limitation of implied warranties o