R0E530640MCU00 User’s Manual 5. Debugging Functions
REJ10J1733-0100 Rev.1.00 Apr. 01, 2008
Page 154 of 229
5.11.6 Changing Address Ranges
Follow the procedure described below to change address ranges.
(1) From the Address Range sheet of the Code Coverage window
1. Select an address range you want to change in the Address Range sheet and while holding it selected, choose Edit Range
from the context menu.
Figure 5.80 Code Coverage window
2. In the Edit Address Range dialog box that is displayed, change the address range.
Figure 5.81 Edit Address Range dialog box