32
2.8.6 Layout of the External Bus Trace Unit Connector
When designing the user system, there are restrictions on the position to install the external bus
trace unit connector. Figure 2.15 shows the external dimensions of the external bus trace unit.
The size of the printed-circuit board of the E200F external bus trace unit is 90 mm × 125 mm. The
size of components around the user system connector must not exceed the limit on component
installation (the height must be 10 mm or less).
10
45
125
90
179
180
1
2
17.5
45
179
180
1
2
Trace bus interface connector
(SAMTEC QSH-090-01-L-D-A: 180 pins)
Unit: mm
Figure 2.15 External Dimensions of the External Bus Trace Unit (on which the Connector is
Installed)