To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C
2.2. Operating Environment The software products provided together with the E8 emulator operate on the host computer and OS version shown in table 2.
Versions of each product differ according to the timing of the E8 emulator shipment. This guide assumes that the E8 emulator software V.2.09 Release
3. Product Specifications 3.1. C Compiler The free evaluation-version C compiler package for the M16C series is provided in the CD-ROM. This C compil
4. Installing the Software 4.1. Installing the Provided Software 4.1.1. Before Starting Installation 1) Do not connect the E8 emulator to the host
(2) The [High-performance Embedded Workshop Install Manager] dialog box will appear. For the first-time installation, [Install Manager Help] will al
(3) The [Input User Information] dialog box will appear. Enter each item and click the [Save] button. Figure 4.3 Entering User Information (4
(5) The [Choice of an installation mode] dialog box will appear. Select the [Install a High-performance Embedded Workshop for the first time] radio
The installation folder may differ depending on the version of the High-performance Embedded Workshop earlier installed. The emulator software
(9) Installation of the High-performance Embedded Workshop starts and the [Choose Setup Language] dialog box will appear. Select [English] and click
(11) The [License Agreement] dialog box will appear. Read the contents and click the [Yes] button. Figure 4.11 License Agreement for the E8 Emu
Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang
(13) The [Select Features] dialog box will appear. Deselect the functions that will not be used, and click the [Next] button. This guide shows an exa
(14) The [Start Copying Files] dialog box will appear. Check the current setting and click the [Next] button. Figure 4.15 E8 Emulator Software
(16) The [InstallShield Wizard Complete] dialog box will appear. Click the [Finish] button. Figure 4.17 Screen Showing Completion of E8 Emulato
Use the [Renesas Tools Support-information] dialog box to confirm user registration. Click the [OK] button to close the window. Figure 4.20 Use
(17) When [Open a precaution file] is selected on the screen showing completion of E8 emulator software, the [Supplementary and Precautions for Emula
(19) The [Renesas AutoUpdate Utility V.*.**.** - InstallShield Wizard] dialog box will appear. Click the [Next] button. The 'V.*.**.**' mea
(21) The [Ready to Install the Program] dialog box will appear. Click the [Install] button. Figure 4.25 Ready to Install the Renesas AutoUpd
(23) After the [AutoUpdate Utility] component has been installed, the [InstallShield Wizard Complete] dialog box will appear. Click the [Finish] butt
(25) The [High-performance Embedded Workshop Install Manager] dialog box will appear. Click the [Finish] button. This completes installation of all s
5. Installing the Driver 5.1. Wizard for Adding Hardware (1) Connect the E8 emulator body to the host computer through the USB cable. (2) The [Fou
www.renesas-electoronics.comIntroductory Guide for R8C/Tiny SeriesApplication Notes8Application NotesRev.1.00 2007.08Renesas E8 On-Chip Debugging Em
(4) Windows® automatically detects and installs the driver. To enable automatic driver detection, the E8 emulator software should be installed in adv
6. Let's Try Using the E8 Emulator This section describes the basic usage of the E8 emulator with regard to the sample program that is to be ins
6.2. Activating the High-performance Embedded Workshop 6.2.1. Activating the High-performance Embedded Workshop Activate the High-performance Embedde
6.3.1. Opening a Workspace (1) The [Welcome!] dialog box will appear on the High-performance Embedded Workshop screen. Figure 6.4 Startup Scr
(2) The [Open Workspace] dialog box will appear. Figure 6.6 Selecting a Workspace File When the software of this product has been installed,
6.3.2. Connecting the E8 Emulator (1) Open the menu for switching a session from the toolbar and select [SessionR8C_E8_SYSTEM]. Figure 6.9 Swit
(2) The [Emulator mode] dialog box will appear. Figure 6.11 [Emulator Setting] Dialog Box In the [Device] menu, the name of the device moun
When the [Enable advanced setting] check box is selected, it is possible to specify the specific address position in the user flash-memory area. The
(5) When the E8 emulator is connected for the first time, the [Please choose driver.] message box will appear. Click the [OK] button. Figure 6.15
(7) If the E8 firmware needs to be updated, the following dialog box appears. Click the [OK] button. Figure 6.17 Updating E8 Firmware (1)
Notes regarding these materials 1. This document is provided for reference purposes only so that Renesas customers may select the appropriate Ren
(9) After the E8 emulator has been connected, [Connected] is displayed on the [Debug] tab of the [Output] window. Figure 6.20 Message Shown
6.3.3. Loading a Sample Program (1) Double-click on the file name ("Tutorial.x30" in this example) that has been expanded under [Download
6.3.4. Opening a Source File (1) Double-click the target source file name in the workspace to open the source code. Figure 6.23 Opening a S
6.3.5. Setting a Breakpoint (1) Scroll the source code display to show line 41 by using the scroll bar. Double-click line 41 Figure 6.24 Se
6.3.6. Executing a Program (1) Select [Reset Go] from the [Debug] menu to execute a program. Figure 6.25 Executing a Program after a Reset 6.3
6.3.8. Checking Variable Contents (1) To show the contents of a variable, select [Symbol] from the [View] menu and select [Watch]. Figure 6.27
(3) The [Add Watch] dialog expression:] edit box and click the [OK] button. box will appear. Enter "a" (symbol name) in the [Variable o
7. Limitations 7.1. Limitations on Free Evaluation-Version C Compiler 1) After the evaluation-version software has been initially installed, the f
Note: When the part number of the micro 5F21194, R5F211A4, or R5F211B4, the [Firmware Location] dialog box, wh n 6.3.2 in this document, will appea
7.3Figure StarterRAM with th. Memory Map 7.1 shows the memory map of R8C/1B. The R5F211B4, which is mounted on the CPU board of Renesas Kit for R8C/
Microsoft, MS, and MS-DOS are registered trademarks of Microsoft Corporation. Windows(R) XP and Windows(R) 2000 Professional are registered trademark
8. Frequently Asked Questions 8.1rred at startup, confirm the following. 1) The USB cable and user system interface cable are correctly connected.
9. Related Documents The E8 emulator and HEW provide many other useful functions not mentioned in this document. Please refer to the following rela
1Ask technical questions about the E8 emulator through the following e-mail addresses. USA: [email protected] @renesas.com0. For More
Revision Record Description Rev. Date Page Summary 1.00 Aug.30.07 — First edition issued
Renesas E8 Emulator Introductory Guide for R8C/Tiny Publication Date: Aug. 30, 2007 Rev.1.00 Published by: Sales S
1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 JapanIntroductory Guide for R8C/Tiny SeriesREJ06J0025-0100Application Notes
Contents 1. Overview ...
Introduction Notes Renesas reserves the right to change, wholly or partially, the specifications, design, user's manual, and other documentatio
1. Overview This introductory guide is intended for first-time users of the E8 emulator. It provides simple descriptions regarding the E8 emulator to
2. Components and Environment This section shows the components of the E8 emulator and the devices and environment needed to use the E8 emulator. Unp
Comentários a estes Manuais