R32C/100 E30A Emulator Debugger Release Notes
REJ10J2119-0100 Rev.1.00 Page 7 of 9
Dec 01, 2010
3. Version Report
This section describes the specification of the changed software.
3.1 R32C/100 E30A Emulator Debugger V.1.02.00
In this version of the R32C/100 E30A emulator debugger, following changes of specifications have been made from the
previous version V.1.01.00.
1. Functional extensions, functional improvements, and specification changes
• Download into external flash memory is now supported.
• The number of breakpoints that can be set for software breaks has been increased from 64 to 256.
• It has been made possible to measure a cycle with which events occur during the section time measurement.
• The frequency input section on the Emulator tab of the Init dialog has been separated into a whole-number
part and a fraction part.
• MCU files corresponding to the following MCUs have been added:
- R32C/117 group
R5F6417A and R5F6417B
- R32C/116A Group
R5F6416JA, R5F6416KA, R5F6416LA, and R5F6416MA
- R32C/117A Group
R5F6417JA, R5F6417KA, R5F6417LA, and R5F6417MA
- R32C/118A Group
R5F6418JA, R5F6418KA, R5F6418LA, and R5F6418MA
- R32C/120 Group
R5F64206, R5F64207, R5F6420A, and R5F6420B
- R32C/121 Group
R5F64216, R5F64217, R5F64218, R5F64219, R5F6421A, R5F6421B, R5F6421C, and R5F6421D
• IO files corresponding to the following groups have been added:
- R32C/116, 117, and 118 groups
- R32C/116A, 117A, and 118A groups
- R32C/120, and 121 groups
- R32C/145 group
- R32C/151, 152, 153, 156, and 157 groups
- R32C/160, and 161 groups
• The debugger response to step execution has been improved.
• When trace mode is selected, the debugger response to Step Over has been speeded up.
2. Limitations solved
• A problem that if, while downloading a program, another application is activated, a state is entered where
there are no debugger responses, has been corrected.
• A problem that if DMAC II of the microcomputer starts while a measurement is taken of the task execution
history, interrupt processing history, etc. of a realtime OS-based program, no measurement results are
displayed in the MR trace window, has been corrected.
3.2 R32C/100 E30A Emulator Debugger V.1.01.00
In this version of the R32C/100 E30A emulator debugger, following changes of specifications have been made from the
previous version V.1.00.00.
1. Functional Extensions and Modifications
• The following windows and script command for the real-time OS debugging are added to this version.
- MR Trace Window
- MR Analyze Window
- MR SYS script command
• The default setting of the trace mode is changed from Trace priority mode to MCU execution priority mode.
On the next start-up of the debugger, the trace mode will be set to the last chosen one (at the last time when