SH7080 Group
A/D Conversion in Single-cycle Scan Mode
REJ06B0699-0100/Rev.1.00 January 2008 Page 14 of 19
(2) A/D Control Register _0 (ADCR_0)
Function: Controls the start of A/D conversion.
Set value: H'0000
Bit Bit Name Set Value Description
15, 14 All 0 Reserved
13 ADST 0
A/D start.
When cleared to 0, the A/D conversion is stopped and the A/D
converter enter the idle state.
When set to 1, A/D conversion is started.
Cleared automatically in single mode upon completion of A/D
conversion on the selected channel.
12 to 0 All 0 Reserved
(3) A/D Trigger Select Register _0 (ADTSR_0)
Function: Enables an external trigger for the start of A/D conversion.
Set value: H'0000 (initial value)
This sample application does not use an external trigger. Thus, this register is not set and its initial values are used as-is.
Bit Bit Name Initial Value Description
15 to 12 TRG11S[3:0] 0000 A/D Trigger 1 Group 1 Select 3 to 0.
Select an external trigger, MTU2 trigger or MTU2S trigger to start
A/D conversion for group 1 when A/D module 1 is in 2-channel
scan mode.
11 to 8 TRG01S[3:0] 0000 A/D Trigger 0 Group 1 Select 3 to 0.
Select an external trigger, MTU2 trigger or MTU2S trigger to start
A/D conversion for group 1 when A/D module 0 is in 2-channel
scan mode.
7 to 4 TRG1S[3:0] 0000 A/D Trigger 1 Select 3 to 0.
Select an external trigger, MTU2 trigger or MTU2S trigger to start
A/D conversion for A/D module 1.
3 to 0 TRG0S[3:0] 0000 A/D Trigger 0 Select 3 to 0.
Select an external trigger, MTU2 trigger or MTU2S trigger to start
A/D conversion for A/D module 1.