Revision Date: A
p
r. 10, 2007
Renesas Microcomputer Development Environment System
SuperH Family / SH7200 Series
SH7260 Series
E10A-USB for SH7261 HS7261KCU01HE
Rev.3.00
SuperH Family E10A-USB Emulator
Additional Document for User’s Manual
Supplementary Information on Using the SH7201
and SH7261
REJ10J1274-0300
Vista de página 0
1 2 3 4 5 6 ... 51 52

Resumo do Conteúdo

Página 1 - Rev.3.00

Revision Date: Apr. 10, 2007Renesas Microcomputer Development Environment SystemSuperH™ Family / SH7200 Series SH7260 Series E10A-USB for SH

Página 2

4 5 mm2-5767004-2Target systemE10A-USB optional 38-pin user system interface cableH-UDI port connector (top view): Area to be kept free of other com

Página 3

5 AUDCKN.C.TCKGNDAU DATA 0GNDAU DATA 1GNDGNDGNDGNDGNDGNDGNDAU DATA 2AU DATA 3UVCCTMSGNDN.C.GND(GND)TDIGNDGNDGNDGNDGNDGNDGNDTDO12345678910111213141516

Página 4

6 Pin 1 markNotes: 1. Input to or output from the user system.2. The symbol (_) means that the signal is active-low.3. The emulator monitors the GND

Página 5 - Contents

7 N.C.N.C._ASEMD (GND)TCKN.C._AUDSYNCN.C.N.C.AUDATA0AUDATA1UVCC_AUDN.C.N.C.TMS_UCON (GND)N.C.AUDCKUVCCN.C.N.C._RESTDIH-UDI port connector (top view)U

Página 6

8 1.5 Recommended Circuit between the H-UDI Port Connector and the MCU 1.5.1 Recommended Circuit (36-Pin Type) Figure 1.5 shows a recommended circ

Página 7

9 When the circuit is connected as shown in figure 1.5, the switches of the emulator are set as SW2 = 1 and SW3 = 1. For details, refer to section 3.

Página 8

10 1.5.2 Recommended Circuit (14-Pin Type) Figure 1.6 shows a recommended circuit for connection between the H-UDI port connector (14 pins) and the

Página 9

11 When the circuit is connected as shown in figure 1.6, the switches of the emulator are set as SW2 = 1 and SW3 = 1. For details, refer to section 3

Página 10

12 1.5.3 Recommended Circuit (38-Pin Type) Figure 1.7 shows a recommended circuit for connection between the H-UDI and AUD port connectors (38 pins

Página 11 - (top view)

13 When the circuit is connected as shown in figure 1.7, the switches of the emulator are set as SW2 = 1 and SW3 = 1. For details, refer to section 3

Página 13

14 Note: When the emulator is used, the AUD trace mode is set without using AUDMD or _AUDRST. If those functions are enabled, do not set these pins

Página 14

15 Section 2 Software Specifications when Using the SH7201 or SH7261 2.1 Differences between the MCU and the Emulator 1. When the emulator system

Página 15

16 3. Low-Power States • When the emulator is used, the sleep state can be cleared with either the clearing function or with the [STOP] button, and

Página 16

17 Table 2.3 Stopping Time by Memory Access (Reference) Method Condition Stopping Time H-UDI read/write Reading of one longword for the internal

Página 17

18 8. Operation while Cache is Enabled When cache is enabled, the emulator operates as shown in table 2.4. Table 2.4 Operation while Cache is En

Página 18

19 9. Multiplexing the AUD Pins The AUD pin is multiplexed as shown in table 2.5. Table 2.5 Multiplexed Functions Function 1 Function 2 PF2/TCLK

Página 19

20 11. Loading Sessions Information in [JTAG clock] of the [Configuration] dialog box cannot be recovered by loading sessions. Thus the TCK value wi

Página 20

21 • CD-ROM When the emulator is in use, the CD-ROM decoder cannot be accessed in the module standby state. Clear the module standby state before ac

Página 21

22 When the emulator is used, note the following to avoid H-UDI read/write access: • Display of the toolchip on the C source ⎯ Disabling H-UDI re

Página 22

23 2.2 Specific Functions for the Emulator when Using the SH7201 or SH7261 2.2.1 Event Condition Functions The emulator is used to set event condit

Página 23

1. This document is provided for reference purposes only so that Renesas customers may select the appropriate Renesas products for their use.

Página 24

24 Table 2.9 Dialog Boxes for Setting Event Conditions Function Dialog Box Address Bus Condition (Address) Data Bus Condition (Data) Bus S

Página 25

25 Sequential Setting: Using the [Combination action (Sequential or PtoP)] dialog box specifies the sequential condition and the start or end of per

Página 26

26 Table 2.10 Conditions to Be Set (cont) Classification Item Description [Ch4, 5] list box Setting is disabled in this MCU. Don’t care [Don’

Página 27

27 Usage Example of Sequential Break Extension Setting: A tutorial program provided for the product is used as an example. For the tutorial program,

Página 28

28 Figure 2.1 [Source] Window at Execution Halted (Sequential Break) If the sequential condition or performance measurement start/end is set, con

Página 29

29 7. If the settings of the Event condition or the sequential conditions are changed during execution of the program, execution will be suspended

Página 30

30 Table 2.12 shows the type numbers that the AUD function can be used. Table 2.12 Type Number and AUD Function Type Number AUD Function HS0005KC

Página 31

31 To set the AUD trace acquisition mode, click the [Trace] window with the right mouse button and select [Setting] from the pop-up menu to display t

Página 32

32 When the AUD trace function is used, select the [AUD function] radio button in the [Trace type] group box of the [Trace mode] page. (a) Branch Tr

Página 33

33 Figure 2.3 [AUD Branch trace] Page (b) Window Trace Function Memory access in the specified range can be acquired by trace. Two memory ranges c

Página 35

34 [Setting Method] (i) Select the [Channel A] and [Channel B] check boxes in the [AUD function] group box of the [Trace mode] page. Each channel

Página 36

35 Note: When [M-Bus] or [I-Bus] is selected, the following bus cycles will be traced. • M-Bus: A bus cycle generated by the CPU is acquired. A bus

Página 37

36 7. If breaks occur immediately after executing non-delayed branch and TRAPA instructions and generating a branch due to exception or interrupt,

Página 38

37 in advance because a user stack is to be used. By default, use of a user stack is disabled. For details on the command, refer to the help file.

Página 39

38 (a) Specifying the measurement start/end conditions The measurement start/end conditions are specified by using Event Condition 1,2. The [Ch1,2,

Página 40

39 Note: When [Ch2 to Ch1 PA] or [Ch1 to Ch2 PA] is selected, to execute the user program, specify conditions set in Event Condition 2 and Event Con

Página 41

40 Table 2.15 Measurement Item Selected Name Option Disabled None Elapsed time AC (The number of execution cycles (Iφ) is set as the measuremen

Página 42

41 Notes: 1. In the non-realtime trace mode of the AUD trace, normal counting cannot be performed because the generation state of the stall or the

Página 44

SuperH™ Family E10A-USB EmulatorAdditional Document for User's ManualSupplementary Information on Using the SH7201 a

Página 45

iContents Section 1 Connecting the Emulator with the User System ...1 1.1 Components of the Emulator ...

Página 46

Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japanhttp://www.renesas.comRefer to

Página 48

SuperH™ Family E10A-USB Emulator Additional Document for User’s Manual Supplementary Information on Using the SH720

Página 50 - RENESAS SALES OFFICES

1 Section 1 Connecting the Emulator with the User System 1.1 Components of the Emulator The E10A-USB emulator supports the SH7201 and SH7261 (R5S7

Página 51

2 1.2 Connecting the Emulator with the User System To connect the E10A-USB emulator (hereinafter referred to as the emulator), the H-UDI port conne

Página 52 - Using the SH7201 and SH7261

3 1.3 Installing the H-UDI Port Connector on the User System Table 1.3 shows the recommended H-UDI port connectors for the emulator. Table 1.3 Re