8.1.3. Programming
① Download
・ Download programming data to S550-SFWv3.
*The programming data shall be downloaded to the main unit for stand-alone programming. (For downloading, see “7.4
Downloading”.)
② Connect the S550-SFWv3 main unit and target board
・ Connect S550-SFWv3 and the target board with the target connecting cable.
*For connection in stand-alone mode, see “4.2 Connection for Stand-alone Programming / Stand-alone Initializing”.
③ Power ON
・ Turn on the target board.
④ Confirm S550-SFWv3 start up
・ For the LED and buzzer status at the startup, see “9.2 LED Status List” and “9.3 Buzzer Sound List”.
⑤ Start programming
・ Press the “START” switch and the programming will start.
⑥ Programming complete
・ Execution result will be output with the LED and buzzer.
(See “9.2 LED Status List” and “9.3 Buzzer Sound List”)
・ Check the execution detail result with the error information display on the center display.
(See “8.4.5 Error Information Display”)
⑦ Power OFF
・ Turn off the target board and disconnect the S550-SFWv3 and the target board.
To continue programming the same data, repeat the procedures 2 through 6 again.
Serial Flash Programmer[S550-SFWv3] Operation Manual 100