Notes: 1. When the second and third ranges are specified, execute the user program after the
measurement start condition is set to Break Condition 1 (or Break Condition 2) and the
measurement end condition to Break Condition 2 (or Break Condition 1).
2.
Step operation is not possible when Break condition 1->2 or Break condition 2->1 is
selected for the PERFORMANCE_SET command or in [Mode] of the [Performance
Analysis] dialog box.
3.
When Break condition 1->2 or Break condition 2->1 is selected in [Mode] of the
[Performance Analysis] dialog box, specify one or more items for measurement.
When there is no item, the error message “Measurement item does not have
specification. Please set up a measurement item.” will be displayed. When no item is
specified for the PERFORMANCE_SET command, the settings of Break condition 1
->2 or Break condition 2->1 will be an error.
(c) Measurement item
Items are measured with [Channel 1 to 4] in the [Performance Analysis] dialog box.
Maximum four conditions can be specified at the same time. Table 2.9 shows the
measurement items (Options in table 2.9 are parameters for <mode> of the
PERFORMANCE_SET command. They are displayed for CONDITION in the [Performance
Analysis] window).