15
4.5 Resulting Dimensions after Connecting User System Interface Board
The resulting dimensions, after connecting the user system interface board to the user system, are
shown in figures 8, 9, and 10.
24.5
55.0
12.5
68.4
30.0
37.5
27.5
29.2
24.5
39.19
39.19
24.5
IC socket
(NQPACK100SD-ND manufactured by
Tokyo Eletech Corporation)
User system
Spacer (φ6.0)
Unit: mm
EV-chip unit
Tolerance: ±1.0 mm
Pin 1
Top view
External bus trace unit
Emulation memory unit
Figure 8 Resulting Dimensions after Connecting User System Interface Board (when
Connecting External Bus Trace Unit, Emulation Memory Unit, and EV-Chip Unit)