To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas
Electronics Corporation took over all the business of both
companies.
Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Vista de página 0
1 2 3 4 5 6 ... 45 46

Resumo do Conteúdo

Página 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Página 2

IILIMITED WARRANTYHitachi warrants its emulator products to be manufactured inaccordance with published specifications and free from defects inmateria

Página 3 - To all our customers

IIIState Law:Some states do not allow the exclusion or limitation of implied warranties or liability forincidental or consequential damages, so the ab

Página 4 - Cautions

IVSAFETY PAGEREAD FIRST• READ this user's manual before using this emulator product.• KEEP the user's manual handy for future reference.Do n

Página 5 - User’s Manual

VWARNINGObserve the precautions listed below. Failure to do sowill result in a FIRE HAZARD and will damage the usersystem and the emulator product or

Página 6

VICAUTIONThis equipment has been tested and found to complywith the limits for a Class A digital device, pursuant to part 15of the FCC Rules. These l

Página 7

iPrefaceThank you for purchasing the H8S/2636, H8S/2638, H8S/2639, H8S/2646, and H8S/2282 seriesE6000 emulator.The H8S/2636, H8S/2638, H8S/2639, H8S/2

Página 8

iiContentsSection 1 Overview ...11.1 Environment Conditions.

Página 9 - IMPORTANT INFORMATION

iiiFiguresFigure 2.1 Default User System Interface Circuit...5Figure 2.2 User S

Página 11

1Section 1 OverviewThe H8S/2636, H8S/2638, H8S/2639, H8S/2646, and H8S/2282 series E6000 emulator (hereafterreferred to as the E6000) is an efficien

Página 12 - SAFETY PAGE

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Página 13

2Table 1.3 H8S/2646 Series MCU and User System Interface CableNo.MCU TypeNumber Package E6000 User System Interface Cables1 HD64F2646HD64F2648R144-pin

Página 14

31.3 Operating Voltage and Frequency SpecificationsTable 1.5 shows examples of the MCU operating voltage and frequency specifications supportedby the

Página 15

4Section 2 User System InterfaceAll user system interface signals are directly connected to the MCU in the E6000 with no bufferingexcept for those l

Página 16 - Contents

5Default:Figure 2.1 Default User System Interface CircuitMode Pins (MD2, MD1 and MD0), NMI and WAIT: The NMI signal is input to the MCUthrough the

Página 17

6PWM1A-H, PWM2A-H:Figure 2.4 User System Interface Circuit for PWM1A-H and PWM2A-H SignalsAN0-AN11, SEG1-SEG24, COM1-COM4, V1-V3, AVcc, AVss and Vre

Página 18

7SEG1-SEG24, COM1-COM4:WARNING1. Always switch OFF the emulator product and usersystem, before setting the switches. Failure to do so willresult in a

Página 19 - Section 1 Overview

8Table 2.1 H8S/2646 Signal Select Switch SettingsSwitch No. Setting to Pin 1 Setting to the Other Pin NotesSW1 PE0 -*SW2 PE1 -*SW3 PE2 -*SW4 PE3 -*SW5

Página 20

9Table 2.1 H8S/2646 Signal Select Switch Settings (cont)Switch No. Setting to Pin 1 Setting to the Other Pin NotesSW31 PB6 SEG15SW32 PB7 SEG16SW33 PF2

Página 21

10Table 2.2 H8S/2648R Signal Select Switch SettingsSwitch No. Setting to Pin 1 Setting to the Other Pin NotesSW1 PE0 SEG1SW2 PE1 SEG2SW3 PE2 SEG3SW4 P

Página 22 - 2.1 Signal Protection

11Table 2.2 H8S/2648R Signal Select Switch Settings (cont)Switch No. Setting to Pin 1 Setting to the Other Pin NotesSW31 PB6 SEG31SW32 PB7 SEG32SW33 P

Página 23 - Default:

Regarding the change of names mentioned in the document, such as Hitachi Electric and Hitachi XX, to Renesas Technology Corp.The semiconductor operati

Página 24 - PWM1A-H, PWM2A-H:

12Table 2.3 H8S/2282 Signal Select Switch SettingsSwitch No. Setting to Pin 1 Setting to the Other Pin NotesSW1 PE0 -*SW2 PE1 -*SW3 PE2 -*SW4 PE3 -*SW

Página 25 - SEG1-SEG24, COM1-COM4:

13Table 2.3 H8S/2282 Signal Select Switch Settings (cont)Switch No. Setting to Pin 1 Setting to the Other Pin NotesSW31 PB6 SEG19SW32 PB7 SEG20SW33 PF

Página 26

14Section 3 Notes on Use3.1 I/O Register Differences between Actual MCU and E6000In the E6000, one evaluation chip emulates several types of MCU. T

Página 27

153.3 Use of an Internal RAM Area as External MemoryAn internal RAM area can be used as an external address when the RAME bit of the SYSCR iscleared t

Página 28

163.6 Selecting the Emulation DeviceWARNING1. Always switch OFF the emulator product and usersystem, before setting the switches. Failure to do so w

Página 29

173.7 Support of the H8S/2639To emulate the H8S/2639, select H8S/2638. However, note that the following limitation.The H8S/2639 incorporates a subcl

Página 30

18Section 4 HDI Parameters4.1 Address AreasTable 4.1 lists the parameters for address areas (Area) that can be specified with HDI commandline interf

Página 31

194.2 Access StatusTable 4.2 lists the parameters for access status (Status) that can be specified with HDI commandline interface or displayed as trac

Página 32 - Section 3 Notes on Use

204.3 I/O ModulesTable 4.3 lists the parameters for I/O module selection in the custom setting of the HDIconfiguration window.Table 4.3 I/O ModulesHDI

Página 33 - 3.5 Hardware Standby

21Section 5 Diagnostic Test ProcedureThis section describes the diagnostic test procedure using the E6000 test program.5.1 System Set-Up for Test Pr

Página 34 - Figure 3.1 JSW6 Setting

CautionsKeep safety first in your circuit designs!1. Renesas Technology Corporation puts the maximum effort into making semiconductor products better

Página 35 - 3.8 Support of the H8S/2282

225.2 Diagnostic Test Procedure Using the Test ProgramInsert the CD-R (HS2646EPI61SR supplied with the E6000) into the CD-ROM drive of the hostcompute

Página 36 - Section 4 HDI Parameters

23It will take about 11 minutes to execute the test program when the host computer usingWindows®95 runs at 166 MHz and the PCMCIA interface card is us

Página 37 - 4.2 Access Status

24Emulator Board Information: Shows the ID number ofMain Board ID H'5 the lower board of theE6000 (always 5).Emulation Board ID H'd Shows th

Página 38 - 4.3 I/O Modules

2503) Testing Firmware RAM :Decode Test. page range H'700 - H'71f ...OK Shows the results ofdecoding test for thefirmware RAM in theE

Página 39

2605) Testing Mapping RAM :Decode Test. page range H'200 - H'27f ...OK Shows the results ofdecoding test for themapping RAM in theE60

Página 40

2710) Testing Emulation RAM Hardware Break : Shows the check resultsSetting up, please wait.. for the illegal access breakGRD Break ...

Página 41 - Message Description

2816) Testing PERM_GA : Shows the check resultsSetting up, please wait.. for the performanceA)Time Measure Test ...OK analysis c

Página 42

H8S/2636, H8S/2638, H8S/2639, H8S/2646, H8S/2282 Series E6000 Emulator HS2646EPI61HSupplementary InformationUser’s ManualRev.5.0 2002.05

Página 44

Cautions1. Hitachi neither warrants nor grants licenses of any rights of Hitachi’s or any third party’spatent, copyright, trademark, or other intellec

Página 46

IIMPORTANT INFORMATIONREAD FIRST• READ this user's manual before using this emulator product.• KEEP the user's manual handy for future refer