Renesas M16C/62P Group Manual do Utilizador Página 25

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 98
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 24
Rev.1.00 2007.11.1
REC10B0002-0100
25
__BasicStopSerialReceiving
Synopsis
<Stop reception>
Boolean Rapi_BasicStopSerialReceiving(unsigned long data)
data Setup data
Description
Stops receiving data in serial communication
[data]
For data, the following values can be set.
RAPI_COM1 UART0 RAPI_COM2 UART1
RAPI_COM3 UART2
Return value
If data reception in serial communication was successfully stopped, RAPI_TRUE is
returned; if failed, RAPI_FALSE is returned.
Functionality
Serial I/O
Reference
__BasicStartSerialReceiving
Remark
For the M16C SI/03 and SI/04, this API cannot be used.
If an undefined value is specified in the argument, operation of the API cannot be
guaranteed.
Program example
#include ”rapi_sif_m16c_62p”
void func( void )
{
/* Stop receiving data in serial communication */
__BasicStopSerialReceiving ( RAPI_COM1 );
}