Renesas TFP-120 Informações Técnicas

Consulte online ou descarregue Informações Técnicas para não Renesas TFP-120. Renesas TFP-120 Technical information Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 31
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas
Electronics Corporation took over all the business of both
companies.
Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Vista de página 0
1 2 3 4 5 6 ... 30 31

Resumo do Conteúdo

Página 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Página 2

IVSAFETY PAGEREAD FIRST• READ this user's manual before using this user system interface cable.• KEEP the user's manual handy for future ref

Página 3 - To all our customers

VWARNINGObserve the precautions listed below. Failure to do sowill result in a FIRE HAZARD and will damage the usersystem and the emulator product or

Página 4 - Cautions

iPrefaceThank you for purchasing this user system interface cable (HS2215ECN61H) for the Hitachi’soriginal microcomputer H8S/2215 series.The HS2215ECN

Página 5 - User’s Manual

iiContentsSection 1 Configuration...1Section 2 Connection Proced

Página 6

1Section 1 ConfigurationCAUTIONUse an IC149-120-043-B5 socket (manufactured byYAMAICHI ELECTRONICS Co., Ltd) for the TFP-120 packageIC socket on th

Página 7 - IMPORTANT INFORMATION

2Table 1 lists the HS2215ECN61H components. Please make sure you have all of thesecomponents when unpacking.Table 1 HS2215ECN61H ComponentsNo. Compon

Página 8 - DISCLAIMER

3Section 2 Connection Procedures2.1 Connecting User System Interface Cable to Emulator StationWARNINGObserve the precautions listed below. Failure

Página 9

4Emulator stationCable body connectorScrews for fixingthe cable bodyUser system interface cableE6000Figure 2 Connecting User System Interface Cable

Página 10 - SAFETY PAGE

52.2 Connecting User System Interface Cable to User SystemWARNINGAlways switch OFF the user system and the emulatorproduct before the USER SYSTEM INTE

Página 11

62.2.3 Inserting Cable HeadCAUTIONCheck the location of pin 1 before inserting.Align pin 1 on the IC socket for an TFP-120 package on the user system

Página 12

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Página 13 - Contents

7Figure 3 Connecting User System Interface Cable to User System

Página 14 - Section 1 Configuration

82.2.5 Fastening Cable BodyConnect the cable body to the cable head.Cable bodyCable headRemove jigPush the remove jigUser systemRemovingFigure 4 Fas

Página 15

9To use the single-chip mode (without USB function) for the H8S/2215 operating mode, removethe EIO board and connect the cable body to the cable head

Página 16

102.3 Recommended Dimensions for User System Mount PadFigure 6 shows the recommended dimensions for the mount pad (footprint) for the user systemwith

Página 17 - User system interface cable

112.4 Dimensions for User System Interface Cable HeadThe dimensions for the user system interface cable head are shown in figure 7.Figure 7 Dimensio

Página 18

122.5 Resulting Dimensions after Connecting User System Interface CableThe resulting dimensions, after connecting the user system interface cable head

Página 19

13Section 3 Installing the MCU to the User SystemCAUTION1. Check the location of pin 1 before inserting.2. Use the screwdriver provided for tighteni

Página 20

14Figure 9 Installing MCU to User System

Página 21 - 2.2.5 Fastening Cable Body

15Section 4 User Interface CircuitThe user system interface cable includes the H8S/2215 microcomputer to emulate the USBfunction. The H8S/2215 user

Página 22 - User system

16Table 2 Selecting User Interface SignalNo. Function Switch Setting Selected FunctionSW1 = 1 48 MHz emulation clockSW1 = 3, SW2 = 1: Setting at shipm

Página 23

Regarding the change of names mentioned in the document, such as Hitachi Electric and Hitachi XX, to Renesas Technology Corp.The semiconductor operati

Página 24

17Section 5 Verifying Operation1. When using the E6000 emulator for the H8S/2215 series, turn on the emulator according to theprocedures described i

Página 25

18Section 6 Notice1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cablehead before inserting the cable h

Página 26

Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corporation puts the maximum effort into making semiconductor products bett

Página 27

H8S/2215 Series TFP-120User System Interface Cable (HS2215ECN61H) for E6000 EmulatorUser’s ManualUser’s Manual Rev.2.0 2002.07

Página 28 - HS2215ECN61H

Cautions1. Hitachi neither warrants nor grants licenses of any rights of Hitachi’s or any third party’spatent, copyright, trademark, or other intellec

Página 29 - SW1 to SW3

IIMPORTANT INFORMATIONREAD FIRST• READ this user's manual before using this user system interface cable.• KEEP the user's manual handy for f

Página 30

IILIMITED WARRANTY Hitachi warrants its user system interface cables to be manufacturedin accordance with published specifications and free from d

Página 31 - Section 6 Notice

IIIState Law: Some states do not allow the exclusion or limitation of implied warranties or liability forincidental or consequential damages, so t

Comentários a estes Manuais