5
2.1.2 Connecting EIO Board 2 to Emulator
1. Remove four screws at the side of the emulator station.
2. Pull up and remove the cover of the emulator casing.
3. Insert connector P5 of EIO board 2 into connector P5 in the emulator station.
4. Fasten EIO board 2 with the provided two screws (M2.6
× 6 mm).
5. Set up the coaxial cable, which has been connected to EIO board 2, into a gutter of the emulator
station.
6. Set the cover of the emulator station and fasten four screws.
E6000
EIO board 2
connector P5
of EIO board 2
connector P5 of
emulator station
Figure 3 Connecting User System Interface Cable to Emulator Station (2)