MITSUBISHI MICROCOMPUTERS
M37270MF-XXXSP
M37270EF-XXXSP, M37270EFSP
SINGLE-CHIP 8-BIT CMOS MICROCOMPUTER with CLOSED CAPTION DECODER
and ON-SCREEN DISPLAY CONTROLLER
54
Fig. 62. Relation between field determination flag and display font
Both H
SYNC
signal and V
SYNC
signal are negative-polarity input
Field
Even
Odd
Field
determination
flag(Note)
Display dot line
selection bit
Display dot line
0 (T2 > T1)
1 (T3 < T2)
0
1
0
1
When using the field determination flag, be sure to set bit 0 of the PWM mode register 1 (address 020A
16
) to “0.”
T2
T3
Character ROM font configuration diagram
Dot line 0
Dot line 1
Odd
Dot line 0
Dot line 1
(n
–
1) field
(Odd-numbered)
T1
0.25 to 0.50[ms] at
f(X
IN
) = 8 MHz
CC mode
•
EXOSD mode
135 79111315
1
3
5
7
9
11
13
15
17
19
21
23
25
26
24
22
20
18
16
14
12
10
8
6
4
2
2 4 6 8 10 12 14 16
1
3
5
7
9
11
13
15
17
19
20
18
16
14
12
10
8
6
4
2
1 3 5 7 9 1113152 4 6 8 10 12 14 16
OSD mode
H
SYNC
V
SYNC
and
V
SYNC
control
signal
in microcom-
puter
Upper :
V
SYNC
signal
Lower :
V
SYNC
control
signal in
micro-
computer
(n) field
(Even-numbered)
(n
+
1) field
(Odd-numbered)
When the display dot line selection bit is “0,”
the “ ” font is displayed at even field, the
“ ” font is displayed at odd field. Bit 7 of the
I/O polarity control register can be read as the
field determination flag : “1” is read at odd field,
“0” is read at even field.
Note : The field determination flag changes at a rising edge of the V
SYNC
control signal (negative-polarity input) in
the microcomputer.
Comentários a estes Manuais