Section 3 Preparing to Connect the Trace Unit
Rev. 2.00 Jan. 28, 2008 Page 19 of 32
REJ10J1422-0200
Section 3 Preparing to Connect the Trace Unit
3.1 Connecting the E200F Trace Unit with the User System
To use the external bus trace function in the emulator, the emulator and the user system must be
connected via the external bus trace unit (R0E0200F0ETU00). Install the trace unit connector on
the user system for connection of the trace unit, referring to section 3.2, Installing the Trace Unit
Connector, in this manual. When designing the user system, read the SH-4A, SH4AL-DSP E200F
Emulator User's Manual and hardware manual for the related MPU.
3.2 Installing the Trace Unit Connector
3.2.1 Trace Unit Connector Installed on the User System
Table 3.1 shows the recommended trace unit connector.
Table 3.1 Recommended Connector
Type Number Manufacturer Specification
QTH-090-04-L-D-A Samtec, Inc. QTH series, 0.5-mm pitch, 180 pins
Note: To connect the connector on the trace unit, do not place any components within 6 mm of
the trace unit connector.