M32R Debugger and Trace 9 Troubleshooting
©1989-2014 Lauterbach GmbH
Troubleshooting
SYStem.Up Errors
The SYStem.Up command is the first command of a debug session where communication with the target is
required. If you receive error messages while executing this command this may have the following reasons.
• The JTAG lines are not connected correctly.
• The target has no power.
• The pull-up resistor between the JTAG[VCCS] pin and the target VCC is too large.
• The target is in reset:
The debugger controls the processor reset and use the RESET line to reset the CPU on every
SYStem.Up. Therefore no external R-C combination or external reset controller is allowed.
• There is logic added to the JTAG state machine:
By default the debugger supports only one processor in one JTAG chain. If the processor is only
one member of a JTAG chain the debugger has to be informed about the target JTAG chain
configuration. Use the SYStem.CONFIG command to specify the position of the device in the
JTAG-chain.
• There are additional loads or capacities on the JTAG lines.
Memory Access Errors
After system up is completed successfully, data can be written to or read from memory. Trying to access
memory not belonging to the memory map of the processor will be refused with the error message
and
When a unrecoverable bus error occurs the target processor has to be reset.
no memory mapped at address D:XXXXXXXX
bus error generated by CPU
Comentários a estes Manuais