R01DS0139ED0100
Data Sheet
Chapter 3 Power supply specification
3.5.5 Condition 6
M2 products only. RESET is used; PTCTL1 is used
Normal operating mode / Serial programming mode / BSCAN mode
Note There is no specification for _RESET rise and fall times.
Parameter Symbol Condition
Ratings
Unit
Min Typ Max
REG0VDD, REG1VDD, IOVDD (rise) to
CVDD (0V) hold time
tR0CH - - 1 ms
REG1VDD (rise) to PTCTL1 (rise) setup
time
tR1PTON - - 1 ms
REG0VDD, IOVDD (rise) to FLMD0,1
(VIL) hold time
tR0MDH 1 - - ms
CVDD (rise) to _RESET (rise) tCRR 0 - - ms
FLMD0,1 (VIH or VIL)
a
to _RESET (rise) tMDRR 1 - - ms
_RESET (rise) to FLMD0,1 (VIH or VIL)
hold time
tRMDH 1 - - ms
FLMD0,1,MODE0,1 (VIL)
a
to _RESET
(fall)
tMDRF 0 - - ms
_RESET (fall) to REG0VDD, IOVDD (fall) tRR0OF 0 - - ms
REG1VDD (fall) to PTCTL1 (fall) tR1PTOF - - 1 ms
PTCTL1 (fall) to CVDD (fall) tPTCOF 0 - 8 ms
a)
In case of BSCAN mode set also the MODE0,1 pins.
REG0VDD
REG1VDD
IOVDD
CVDD
FLMD0
P0_1/FLMD1
3.0V
VIL
VIL
1.1V
PTCTL1
tR0MDH
tR1PTON
3.0V
tPTCOF
tR1PTOF
_RESET
tRR0OF
tMDRF
tCRR
tR0CH
VIH
VIH
tMDRR
tRMDH