To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas
Electronics Corporation took over all the business of both
companies.
Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Vista de página 0
1 2 3 4 5 6 ... 33 34

Resumo do Conteúdo

Página 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Página 2

IV SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for futur

Página 3 - User’s Manual

V WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emul

Página 5

i Preface Thank you for purchasing this user system interface cable (HS3064BECH61H) for the Renesas’ original microcomputers H8/3048 group, H8/3052 g

Página 6

ii Contents Section 1 Configuration...1 Section 2 Connection Pr

Página 7 - IMPORTANT INFORMATION

1 Section 1 Configuration CAUTION Use an IC149-100-054-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100B/ TFP-1

Página 8 - DISCLAIMER

2 Table 1 lists the HS3064BECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS3064BECH61H Components No

Página 9

3 Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below.

Página 10 - SAFETY PAGE

4 2. After making sure the direction of the cable body connector is correct, firmly insert the cable body connector into the emulator station socket

Página 11

5 2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USE

Página 12

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Página 13 - Preface

6 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-100B/TFP-100B package

Página 14 - Contents

7 Fasten the user system interface cable head to the IC socket for an FP-100B/TFP-100B package on the user system with the four screws (M2.6 x 12 mm;

Página 15 - CAUTION

8 2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable bodyCable headUser systemRemove jigPush the remove jigs.Removing Figure

Página 16

9 2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system w

Página 17

10 2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Uni

Página 18 - 6 mm) (figure 2)

11 2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable

Página 19

12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver

Página 20

13 MCUPin 1IC socket (IC149-100-054-B51manufactured by YAMAICHI ELECTRONICS Co., Ltd.)User systemScrews (M2.6 x 6 mm)with flat washersSocket cover Fi

Página 21

14 Section 4 Verifying Operation 1. Start up the emulator according to the procedures described in the H8/3048 Group, H8/3052 Group, H8/3062 Group

Página 22 - 2.2.5 Fastening Cable Body

15 Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the ca

Página 23 - 0.50 ± 0.05

H8/3048 Group, H8/3052 Group, H8/3062 Group, H8/3067 Group, H8/3007 Group FP-100B/TFP-100B User System Interface Cable for E6000 EmulatorUser’s Manual

Página 24 - Tolerance: ±0.5 mm

16 6. The P1 jumper is used for testing. A jumper pin is inserted in pin 1 side. Do not remove the inserted jumper pin. CAUTION Insert the

Página 25 - (IC149-100-054-B51

H8/3048 Group, H8/3052 Group, H8/3062 Group,H8/3067 Group, H8/3007 Group FP-100B/TFP-100BUser System Interface Cablef

Página 26

Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japanhttp://www.renesas.comRefer to

Página 28

1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 JapanH8/3048 Group, H8/3052 Group, H8/3062 Group, H8/3067 Group, H8/3007 Group FP-100

Página 30

1. This document is provided for reference purposes only so that Renesas customers may select the appropriate Renesas products for their use

Página 32 - RENESAS SALES OFFICES

I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy

Página 33

II LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and f

Página 34 - H8/3067 Group, H8/3007 Group

III State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages,

Comentários a estes Manuais

Sem comentários