Renesas H8S/2138 Series Manual Página 76

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 148
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 75
Microcomputer Technical Q&A
68
Q&A No.: QAH8S-057
Category: Pins
Subject: Built-In MOS Pull-Ups in Reset
Question
Can built-in MOS pull-ups be turned on in the reset state?
Answer
In a manual reset, I/O port states are held, and therefore built-in MOS pull-ups can be turned on.
In a power-on reset, I/O ports are initialized, and therefore built-in MOS pull-up settings are
cleared.
Applicable Products
Applicability Series Applicability Series Applicability Series
Yes Entire H8S Series H8S/2655 H8S/2350
H8S/2355 H8S/2357 H8S/2345
H8S/2245 H8S/2148 H8S/2144
H8S/2138 H8S/2134 H8S/2128
H8S/2124
Vista de página 75
1 2 ... 71 72 73 74 75 76 77 78 79 80 81 ... 147 148

Comentários a estes Manuais

Sem comentários