4.6 Connecting to the Target System
(1) For 4502 and 4507 Groups
How to connect the M34502T-MCU to the target system when using for 4502 and 4507 Groups
is shown below.
Make note of the fact that it is not possible to connect the M34502T-MCU directly to the foot
pattern of the MCU package (24P2Q-A).
a. Connecting to 2.54-mm-pitch Dual-in-line Pins on the Target System
Use the 26-wire normal-pitch cable (included) to connect the 26-pin dual-in-line pins on the
target system. The following products are required for connection to the target system.
60-wire half-pitch cable (40 cm)
Pitch converter board PCA4029
26-wire normal-pitch cable (10 cm)
Figure 4.8 shows the M34502T-MCU board connected to the target system using the 26-wire
normal-pitch cable. Table 4.8 lists the connector signal assignments of the 26-wire normal-pitch
cable. And Figure 4.9 shows the pin layout of the 26-wire normal-pitch cable.
Figure 4.8 Connection to the target system using dual-in-line pins