V850E2/MN4 Timer Array Unit Control
R01AN0922EJ0100 Rev.1.00 Page 29 of 54
Jan 13, 2012
TAUAn channel dead time output enable register (TAUAnTDE)
This register enables/disables the dead time operation for each channel. In this sample program, the TAUA disables
dead time operation.
Figure 4.24 TAUAnTDE Register Format
Setting example
TAUA1TDE = 0x0000; /* dead time prohibit */
TAUAn channel dead time output mode register (TAUAnTDM)
This register specifies when dead time is added during dead time output. This sample program does not use the dead
time function.
TAUAn channel dead time output level register (TAUAnTDL)
This register selects the phase period to which the dead time is added. This sample program does not use the dead time
function.