(7) To enable the event condition that has been set, uncheck the [Free Trace] check box on the [General] page.
This will add pages [1] to [4] (see figure 6.45, [Trace Acquisition] dialog box).
(8) Select page [1] and click the [Range] radio button in the [Conditions] group box. This will display the [Range
Event] combo box and the [Edit…] button (see figure 6.46, [Trace Acquisition] dialog box).
(9) Click the [Range Event] combo box to select the event you have registered. The event is now enabled. Click
the [OK] button to complete the trace setting.
Figure 6.52 [Trace Acquisition] Dialog Box (Setting Completed)
(10) Make the setting such that the break occurs after the instruction at the address on the line that has ‘p_sam-
>s0=a[0];’ within the tutorial function (H’00001082 in this example) (for details on this, refer to
section 6.15.1, PC Break Function).
(11) Select [Reset Go] from the [Debug] menu. Processing stops when the break condition is satisfied, and the
[Trace] window then displays the following content.
Figure 6.53 [Trace] Window (Displaying the Result)
If you have trouble viewing a column, drag the header (vertical) bars below the title bar to adjust the width
of the column.