361
(2) [Platform] Sheet
Selecting the [Platform] tab on the [Status] window displays this sheet.
Table 8.4 [Platform] Sheet Items
[Item] Column [Status] Column
Connected To: Displays emulator name (driver used).
CPU Displays the target MCU name.
Mode Displays the selected mode.
Clock source Displays the selected clock.
Subclock source Displays the selected sub-clock.
Run status Displays the execution status.
Break: The user program breaks
Running: The user program is running
Cause of last break Displays the cause of the emulator stopped at a break. If a program
breaks in the sub-active state, '(SubActive)' will be displayed after the
cause of the break.
Ready: User program not executed (immediately after starting the HEW)
User Break: Break by the user
PC Break: Break by program breakpoint
On Chip Break A: Break by hardware PC Break
Complex Event System: Break by complex event system
Stepping Completed: Break by stepping completed
Stepping Aborted: Break by stepping aborted
ROM Write Access Break: Break by writing to ROM
Write-protect Access Break: Break by writing to a read-only memory
Unused Area Access Break: Break by accessing to a guarded memory
Performance Break: Break by Performance Analysis
Invalid breakpoint: Break by a break instruction without PC Break
Event Time Count Displays the measured result of the timer between events.
Run Time Count Displays the total execution time of the program.
(3) [Events] Sheet
Selecting the [Events] tab on the [Status] window displays this sheet.
Table 8.5 [Events] Sheet Item
[Item] Column [Status] Column
Resources Displays the resource information and the information on events such as
the breakpoint.
Vista de página 388