H.2 Diagnostic Test Procedure Using Test Program
Insert the CD-R (HS2628EPI61SR supplied with the emulator) into the CD-ROM drive of the host computer,
move the current directory to <Drive>:\Diag with a command prompt, and enter one of the following commands
according to the PC interface board used to initiate the test program:
1. PCI bus interface board (HS6000EIC01H or HS6000EIC02H)
> TM2628 –PCI (RET)
2. PCMCIA interface card (HS6000EIP01H)
> TM2628 –PCCD (RET)
3. LAN adapter (HS6000ELN01H)
> TM2628
ELN (RET)
4. USB adapter (HS6000EIU01H)
> TM2628
USB (RET)
The HEW must be installed before the test program is executed.
Be sure to initiate the test program from <Drive>:\Diag. Do not initiate it from a directory other than
<Drive>:\Diag, such as > <Drive>:\Diag\TM2628 –PCI (RET). If the test program is initiated when the current
directory is not <Drive>:\Diag, the test program will not operate correctly.
When –S is added to the command line such as >TM2628 –PCI –S (RET), steps 1 to 19 will be repeatedly
executed. To stop the execution, enter Q.
Notes: 1. <Drive> is a drive name for the CD-ROM drive.