R8C/14 Group, R8C/15 Group 6. Voltage Detection Circuit
Rev.2.10 Jan 19, 2006 Page 31 of 253
REJ09B0164-0210
6.1 Monitoring VCC Input Voltage
6.1.1 Monitoring Vdet1
Vdet1 cannot be monitored.
6.1.2 Monitoring Vdet2
Set the VCA27 bit in the VCA2 register to “1” (voltage detection 2 circuit enabled). After td(E-A) (refer
to 19. Electrical Characteristics) elapse, Vdet2 can be monitored by the VCA13 bit in the VCA1
register.