156
Table 5.8 BREAKCONDITION_SET Command Parameters (cont)
Parameter Type Description
<datawidth> Keyword Data bus access conditions
Set one of the following keywords:
byte: byte access
word: word access
long: longword access
x: X-Bus data bus access
y: Y-Bus data bus access
<asid> Numerical value ASID value from 0 to H'FF.
<r/w> Keyword Bus cycle read/write conditions
Set either of the following keywords:
read: read cycles
write: write cycles
<access> Keyword Bus cycle access type
dat: execution cycles
<count> Numerical value Set satisfaction count from 1 to H'FFFF
<ldtlb> Keyword Set LDTLB instruction execution as a break condition
break: Breaks when the LDTLB instruction is executed.
<io> Keyword Set internal I/O access condition as a break condition.
break: Breaks when the internal I/O area is accessed.
Note: The parameters for this command differ according to the product. For the
specifications of each product, refer to the online help.