Renesas SH7641 Informações Técnicas Página 180

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 250
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 179
158
5.2.8 BREAKPOINT: BP
Description:
Sets software breakpoints.
Note: The function will differ according to the devices used.
Format:
bp <address> [<address_space> [<asidopt>]]
<address_space> = space <space>
<asidopt> = asid <asid>
Table 5.9 BREAKPOINT Command Parameters
Parameter Type Description
<address> Numerical value Breakpoint address
When an odd address is set, the address is rounded down to
an even address.
<space> Keyword Breakpoint address area
Set either of the following keywords:
physical: physical address
virtual: virtual address
<asid> Numerical value ASID value of a breakpoint when virtual is set to the <space>
parameter.
Note: When virtual is set and the <asidopt> item is omitted in the <address_space> item, a
breakpoint is set to a virtual address corresponding to the ASID value at command input.
Note: The parameters for this command differ according to the product. For the
specifications of each product, refer to the online help.
Vista de página 179
1 2 ... 175 176 177 178 179 180 181 182 183 184 185 ... 249 250

Comentários a estes Manuais