Renesas SH7641 Informações Técnicas Página 237

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 250
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 236
215
2. Displaying the measured result
The measured result is displayed in the [Performance Analysis] window or the
PERFORMANCE_ANALYSIS command with hexadecimal (32 bits).
Figure 6.16 [Performance Analysis] Window
Note: If a performance counter overflows as a result of measurement, ******** will be
displayed.
3. Initializing the measured result
To initialize the measured result, select [Initialize] from the popup menu in the [Performance
Analysis] window or specify INIT with the PERFORMANCE_ANALYSIS command.
6.5.10 Notes on Using the Profile Function
1. Errors
The profile function internally breaks user program execution, collects the measured data, and
re-executes the user program.
Since the function also counts when the measured item is generated at break or re-execution,
an error will be included in the measured profile value.
The measured value of this function should be the target.