28
3.4 Reading and Displaying the Emulator Information Regularly
Use the [Extended Monitor] window to know the changing information on the emulator no matter the user
program is running or halted.
Note: The extended monitor function does not affect the execution of the user program since it monitors the
user system or the signal output from the target MCU in the emulator by using the emulator’s hardware
circuit.
3.4.1 Opening the [Extended Monitor] Window
Selecting [View -> CPU -> Extended Monitor] or clicking the [Extended Monitor] toolbar button (
) displays
this window. The interval of updating the display is approximately 1,000 ms during user program execution or
5,000 ms while breaking, respectively.
Figure 3.12 [Extended Monitor] Window