4.16.2 Displaying Trace Information by the Trace Stop Function
While the trace stop function is in use, acquisition of trace information stops when a specified condition is
satisfied. The user can check the program flow by the trace information without breaking the user program
execution.
(1) Delete all the break conditions that have been set. Uncheck [Free Trace] on the [Condition] page of the
[Trace Acquisition Properties] dialog box (otherwise, the free trace mode will be selected).
(2) Select [1] from the list box on the [Condition] page of the [Trace Acquisition Properties] dialog box and then
click [Edit…]. The [Trace Acquisition Condition Channel 1] dialog box is displayed. Select the [Trace Stop]
radio button in the [After Condition Match] group box on the [Action] page.
Figure 4.41 [Trace Acquisition Condition Channel 1] Dialog Box (Trace Stop)